Home News Sitemap Privacy LoginLogin
FORA D30 Blood Glucose plus Pressure Monitoring System

Interactive Demo

Key Features

  • 2-in-1 combination Blood Glucose and Blood Pressure measurement.
  • Advanced bilingual (English/ Spanish ) talking function embedded that guides users through each step with a repeat function and volume control.
  • Bluetooth Connectivity: Test results can be wirelessly and accurately transferred to the internet or a personal computer.
  • Supported by FORA TeleHealth System: FORA Telehealth System assists you to transfer, organize and analyze data efficiently and wisely.
  • Tiny blood sample - 0.7μl
  • Quick result - 7 seconds
  • Alternative Site Testing
  • 400 memory sets with date & time and 7, 14, 21, 28, 60, 90 days average available

Specification

Blood Test Volume (uL) 0.7
Reaction Time (seconds) 7
Measurement Range 20~600 mg/dL (1.1~33.3 mmol/L)
Code No Coding
Enzyme Type GOD
Hematotocrit Range 20 to 60%
Memory Sets 400
Alternative Site Testing Yes
Strip Ejection Yes
AC/PC Recording Yes
QC Record Yes
Daily Alarm 4
Ketone Warning Yes ≧240mg/dL (13.3 mmol/L)
Day Average 7/14/21/28/60/90 days
Accuracy of Pressure ±3mmHg or ±2% of reading
Accuracy of Heart Rate ±4% of reading
BP Measuring Unit mmHg or KPa
Wrist / Arm type Arm
IHB Detection Yes
Automated Average Function (AVG) Yes
Talking Function Advanced (English & Spanish)
Data Output RS232 / Bluetooth
Power Source 4 x AA or 6V Adapter
Dimension (inch) 5.98" x 3.74" x 2.16"
Weight (lb) without Batteries 0.61

How To Use (Blood Glucose)

1.Insert a test strip to turn on the meter. The sequence of LCD displays is: “CHK” and “ ” →flashing “ ” with date and time. 2.Hold the pre-set lancing device firmly against the puncture site. Press the release button to obtain a drop of blood.
3. While “ ” is flashing on the display, touch the absorbent hole on the tip of the test strip to the drop of blood until the confirmation window is completely filled. 4.After the meter counts to 0, your test result will appear along with the date and time and will be automatically stored in memory.
 
5.Eject the used test strip. Dispose of the used strip and lancet safely.  

How To Use (Blood Pressure)

1.Sit down for at least 10 minutes before measuring. 2.Stretch your left arm forward with your palm facing up. Slide the cuff onto your left arm, above your elbow. The red line on the edge of the cuff should be approximately 0.8 to 1.2 inch (2 to 3 cm) above your elbow.
3.Arrange tubing over the main arteries inside of your arm. Press . 4.Relax and make sure the cuff is at the same height as your heart.
5.Measurement is in progress: Start inflation → Stop inflation when cuff pressure is enough → Cuff pressure deflates steadily. 6.The monitor will display the systolic pressure, diastolic pressure, and heart rate along with the date and time. Press to switch off.

 

Downlaod Center